ANANTAInnovations & Integrated Solutions
AISPL/SOLUTIONS/Healthcare Facilities & Nurse Calling Infrastructure
Topology Ref: AISPL-REF-HLTH-02

Healthcare Facilities & Nurse Calling Infrastructure

Fail-safe galvanic isolation, ultra-fast response, and hygienic patient touchpoints.

Architecture Spec Summary
TOPOLOGY:AISPL-REF-HLTH-02
TIERS:3-Tier Deterministic
COMMISSIONING:Fieldbus Native
Sector Challenge & Vulnerability

The Operational Bottleneck

Hospitals cannot tolerate earth leakage faults or power dropouts in critical treatment zones (ICUs, operating theatres). Conventional consumer automation lacks galvanic segregation and creates electromagnetic interference with sensitive electro-medical instrumentation.

Engineered Solution Topology

AISPL 3-Tier Hardware Response

Medical-grade nurse call annunciators, earth leakage supervision, and cleanroom lighting automation.

Section 2.0 — System Architecture

Deterministic 3-Tier Topology

Strict functional separation guarantees that field sensory inputs, high-speed switching logic, and cloud telemetry run without bus resource contention.

TIER 01INPUT & SENSING

Field Devices

  • ›Hermetically Sealed Silicone Bedside Call Pendants (IP67)
  • ›Ablution Pull-Cord Emergency Switches
  • ›Staff Presence & Code-Blue Cancellation RFID Wall Stations
TIER 02CONTROL & POWER

Core Actuators

  • ›LCP-230V High-Sensitivity Earth Leakage Sensing Unit
  • ›DB-9W-CC-60Min Emergency Battery Backup LED Driver
  • ›Medical Isolated Power Supply (MIPS) Supervision Node
TIER 03GATEWAY & BMS

Supervisory Uplink

  • ›Optically Isolated RS-485 Multi-Drop Bus (1500V RMS Isolation)
  • ›Nurse Station Master Touchscreen Console with Audio Annunciation
  • ›HL7 / FHIR Interface Engine for Hospital Information System (HIS)
Key Architectural Benchmarks:
✓Full compliance with IEC 60601-1-2 EMC directives for immunity against electrosurgical interference.
✓Independent LiFePO4 battery pack ensures 60 minutes of uninterrupted egress lighting during total blackout.
✓Continuous line supervision detects open-circuit and shorted fieldbus cables with millisecond-grade fault alerts.
Section 3.0 — Procurement Specification

Validated Bill of Materials (BOM)

TOPOLOGY BOM: AISPL-REF-HLTH-02
#PART NUMBERDESCRIPTION & RATINGESTIMATED QUANTITYSUBSYSTEM ROLE
1LCP-230VLeakage Current Protector, 230VAC, 10mA ultra-sensitive ground leakage trip1 per patient isolation panelPatient Shock & Leakage Prevention
2DB-9W-CC-60MinEmergency Constant Current LED Driver with internal LiFePO4 battery pack, 60-min autonomy1 per clinical luminaireCode-Compliant Egress Illumination
3NC-STATION-M8Corridor Overdoor Tri-Colour LED Annunciator with built-in AU999 bus transceiver1 per patient roomVisual Alarm Dispatch
Section 4.0 — Hardware Inventory

Included Hardware Modules

VIEW HARDWARE CATALOGUE
DCS-200W / DCS-200W-UDALI Controllers

DALI Controlled Contactor

Precision 16A inrush zero-voltage crossing switching contactor with native IEC 62386-101/102 bus isolation.

200VA continuous / 16A inrushInspect Specs
LCP-230V / LCP-250VProtection Modules

Leakage Current Protector

Sub-25ms micro-differential leakage protection designed for critical patient-care and precision industrial facilities.

16A / 25A Continuous Thermal RatingInspect Specs
DB-9W-CC-60MinEmergency Drivers

Emergency LED Driver with Battery Backup

Constant-current architectural emergency driver with automatic DALI test compliance and LiFePO4 battery pack.

9W Emergency Output / 60 Min RuntimeInspect Specs

Request Architecture Engineering Review

Receive customized single-line diagrams, circuit calculations, and quantity takeoffs for AISPL-REF-HLTH-02.

Request Solution BOM Quote