Energy Management & Power Quality

Seamless phase transfer, active power conditioning, and real-time telemetry.

Architecture Spec Summary
TOPOLOGY:AISPL-ARCH-PWR-01
TIERS:3-Tier Deterministic
COMMISSIONING:Fieldbus Native
Sector Challenge & Vulnerability

The Operational Bottleneck

Commercial facilities, data hubs, and critical manufacturing lines suffer from phase unbalance, neutral-to-ground noise, and grid voltage sags. Conventional mechanical transfer switches produce contact arcing and take 30–50ms to switch, triggering equipment resets and semiconductor stress.

Engineered Solution Topology

AISPL 3-Tier Hardware Response

Power monitoring, active harmonic conditioning, galvanic fault isolation and dual-source automatic transfer systems.

Section 2.0 — System Architecture

Deterministic 3-Tier Topology

Strict functional separation guarantees that field sensory inputs, high-speed switching logic, and cloud telemetry run without bus resource contention.

TIER 01INPUT & SENSING

Field Devices

  • ›Three-Phase 415 VAC Grid Mains Feed
  • ›Dedicated Auxiliary Generator Bus
  • ›Rooftop PV Micro-Inverter Solar Input
TIER 02CONTROL & POWER

Core Actuators

  • ›DSAPS-2S-100W-V2 Solid-State Phase Shifter (sub-10ms transfer)
  • ›LCP-230V Active Earth Leakage Sensing Unit (<10mA trip)
  • ›Active Harmonic Filtering & Soft-Start Zero-Cross Switching
TIER 03GATEWAY & BMS

Supervisory Uplink

  • ›WiseGrid AnalytIQ High-Speed Edge Telemetry Node
  • ›Galvanically Isolated MODBUS RTU Fieldbus Loop
  • ›TLS 1.3 Secure MQTT Telemetry Broker to Facility SCADA
Key Architectural Benchmarks:
✓Sub-10ms phase transfer ensures continuity for switch-mode power supplies without triggering equipment resets.
✓3750 VAC galvanic dielectric withstand protecting all low-voltage control buses from 230V line transients.
✓True RMS current and harmonic analysis with onboard non-volatile telemetry spooling for zero data loss.
Section 3.0 — Procurement Specification

Validated Bill of Materials (BOM)

TOPOLOGY BOM: AISPL-ARCH-PWR-01
#PART NUMBERDESCRIPTION & RATINGESTIMATED QUANTITYSUBSYSTEM ROLE
1DSAPS-2S-100W-V2Dual Source Automatic Phase Shifter, 230VAC, 100W/channel, sub-10ms solid-state commutation1 per critical distribution boardPrimary/Secondary Phase Shifting
2LCP-230VLeakage Current Protector, 230VAC, 10mA threshold, DIN-rail mounting1 per branch circuitGalvanic Fault Isolation
3DCS-200W-UDALI-2 Contactor & Power Switch, 200W rating, DALI-2 DT7 / AU999 protocolAs required by sub-loadsAuxiliary Load Shedding
4WG-ANALYTIQ-01WiseGrid Edge Analytics Node, Ethernet + RS-485 MODBUS RTU, 16-bit ADC True-RMS1 per electrical roomSupervisory Power Telemetry
Section 4.0 — Hardware Inventory

Included Hardware Modules

VIEW HARDWARE CATALOGUE
DCS-200W / DCS-200W-UDALI Controllers

DALI Controlled Contactor

Precision 16A inrush zero-voltage crossing switching contactor with native IEC 62386-101/102 bus isolation.

200VA continuous / 16A inrushInspect Specs
DSAPS-2S-100W-V2Phase Selectors

Dual Source Automatic Power Shifter

Sub-millisecond transfer between grid mains and auxiliary secondary AC lines with zero cross-conduction.

100W Continuous / 250W PeakInspect Specs
LCP-230V / LCP-250VProtection Modules

Leakage Current Protector

Sub-25ms micro-differential leakage protection designed for critical patient-care and precision industrial facilities.

16A / 25A Continuous Thermal RatingInspect Specs
WISEGRID-4G-PROEdge Gateways & Telemetry

WiseGrid Industrial 4G Edge Gateway

Sub-millisecond telemetry bridge with zero-conduction galvanic protection

Request Architecture Engineering Review

Receive customized single-line diagrams, circuit calculations, and quantity takeoffs for AISPL-ARCH-PWR-01.