ANANTAInnovations & Integrated Solutions
AISPL/TECHNOLOGIES/Smart Infrastructure
Engineering Discipline Specification

Smart Infrastructure

Integrated hardware infrastructure for modern enterprise commercial towers, airports, and medical complexes. AISPL controllers orchestrate emergency egress lighting, automated phase backup, and HVAC load shedding.

Domain Quick Reference
KEY CHIPS & PROTOCOLS:
BMS GatewaysEnergy AuditBACnet IP
R&D FACILITY:MUMBAI LAB
Section 1.0 — Technical Methodology

Core Engineering Principles

01

Autonomous Subsystem Operation

Controllers function autonomously at the local distribution board level without requiring cloud server connectivity.

02

Direct BMS Protocol Mapping

Standard BACnet/IP and Modbus register maps allowing immediate drop-in integration with Schneider, Johnson Controls, and Honeywell BMS.

03

Life Safety Egress Override

Dedicated dry-contact fire-alarm inputs triggering immediate 100% illumination override across all emergency drivers.

Section 2.0 — Signal & Logic Flow

System Architecture Flow

End-to-end signal processing and control path engineered for Smart Infrastructure.

01

Floor Distribution Board

DIN-rail mounted AISPL controllers seated directly in the main electrical distribution panel.

02

Local Sensor Feedback Loop

PIR motion, daylight harvesting, and current transformer feedback.

03

Panel-to-Panel Interlock

High-speed AU999 bus coordinating multi-floor load shedding during generator start.

04

Supervisory BMS Feed

High-level BACnet MS/TP or Modbus TCP aggregation to facility headend.

Section 3.0 — Engineering Attributes

Domain Technical Benchmarks

PARAMETER / SPECIFICATIONENGINEERING METRIC / IMPLEMENTATION
Mounting Form FactorStandard 35mm DIN-Rail (EN 50022)
BMS CompatibilityBACnet MS/TP, Modbus TCP/IP
Fire Alarm InputNormally Closed Dry Contact with EOL Resistor
CertificationsCE, RoHS, IEC 60947
Section 4.0 — Hardware Implementations

Related Hardware & Controllers

VIEW COMPLETE CATALOGUE
DSAPS-2S-100W-V2Power Supplies & Shifters

Dual Source Automatic Power Shifter

Sub-millisecond transfer between grid mains and auxiliary secondary AC lines with zero cross-conduction.

AU999 2-WireDry Contact
100W Continuous / 250W PeakFull Specs
DB-9W-CC-60MinEmergency & Auxiliary Power

Emergency LED Driver with Battery Backup

Constant-current architectural emergency driver with automatic DALI test compliance and LiFePO4 battery pack.

DALI-2DALI Part 202
9W Emergency Output / 60 Min RuntimeFull Specs

Have a technical requirement in Smart Infrastructure?

Our senior engineering team in Mumbai can evaluate your schematics or custom specification.

Discuss Engineering Spec