Smart Commercial Buildings & Facility Automation
Enterprise lighting automation, HVAC integration, and tenant sub-metering.
The Operational Bottleneck
Commercial office complexes waste up to 35% of total electrical energy through unoccupied zone over-illumination, unbalanced 3-phase floor distribution, and lack of granular sub-metering for tenant billing.
AISPL 3-Tier Hardware Response
Scalable commercial building infrastructure unifying DALI-2 daylight harvesting, BACnet HVAC integration, and automated load shedding.
Deterministic 3-Tier Topology
Strict functional separation guarantees that field sensory inputs, high-speed switching logic, and cloud telemetry run without bus resource contention.
Field Devices
- ›DALI-2 Multi-Sensors (Lux Daylight Harvesting + PIR Occupancy)
- ›BACnet MS/TP Digital Temperature & Humidity Thermostats
- ›Current Transformer (CT) Sub-Distribution Floor Metering Loops
Core Actuators
- ›DCS-200W-U Architectural Zero-Cross Lighting Contactors
- ›Multi-Channel 0-10V / DALI Variable Speed Fan Coil Relays
- ›LCP-230V Earth Leakage Monitoring Units for Wet Services & Pantries
Supervisory Uplink
- ›BACnet/IP to DALI-2 Multi-Master Enterprise Controller
- ›MODBUS RTU Isolated RS-485 Sub-Meter Aggregator
- ›Central Building Management System (BMS) Cloud Telemetry Connector
Validated Bill of Materials (BOM)
| # | PART NUMBER | DESCRIPTION & RATING | ESTIMATED QUANTITY | SUBSYSTEM ROLE |
|---|---|---|---|---|
| 1 | DCS-200W-U | DALI-2 Contactor & Power Switch, 200W rating, DIN-rail mounting | 12 per floor panel | Floor Lighting Circuit Switching |
| 2 | LCP-230V | Active Earth Leakage Sensing Unit, 230VAC, 10mA trip threshold | 4 per floor (Pantry & Server Hubs) | Branch Earth Fault Interception |
| 3 | DSAPS-2S-100W-V2 | Dual Source Automatic Phase Shifter, 230VAC, sub-10ms transfer | 2 per floor electrical riser | Emergency Automation Control Supply |
| 4 | BMS-GW-BACNET | Multi-Protocol DALI-2 to BACnet/IP Edge Controller, 4-DALI line capacity | 1 per building zone | Supervisory BMS Gateway |
Included Hardware Modules
DALI Controlled Contactor
Precision 16A inrush zero-voltage crossing switching contactor with native IEC 62386-101/102 bus isolation.
Dual Source Automatic Power Shifter
Sub-millisecond transfer between grid mains and auxiliary secondary AC lines with zero cross-conduction.
Leakage Current Protector
Sub-25ms micro-differential leakage protection designed for critical patient-care and precision industrial facilities.
Emergency LED Driver with Battery Backup
Constant-current architectural emergency driver with automatic DALI test compliance and LiFePO4 battery pack.
Request Architecture Engineering Review
Receive customized single-line diagrams, circuit calculations, and quantity takeoffs for AISPL-REF-BLD-01.